Cell Relay Archive[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index][Thread Index][Author Index][Subject Index] Re: Siemens SMDS switch and Kentrox SDSU
> > I've been working over the past few days to get a 4Mb SMDS line > running between a Siemens SMDS switch (used by Bell Atlantic in > the DC area) and a Kentrox DSU connected to a Cisco 7010 HIP > interface. > > We were able to get it running today after the following suggestion > from BA. The switch is using a 32 bit CRC. It was suggested that > the Kentrox DSU and the Cisco be changed to use a 16 bit CRC word > while leaving the switch at using a 32 bit CRC. No real explanation > was provided so I was wondering if someone with much more insight > than I have could shed some light on this (if it indeed makes sense). > > Thanks, > Jeff > Hey Jeff, Try calling Jasbal Singh, at bell-atlantic. He's considered the guru on frame relay. and might know of some one who can give you further insight. -Sae
|
|