Re: IMA: Handling anomaly condition

  • From: "S.Ramkumar" <ram@wipinfo.soft.net>
  • Date: 7 Jun 1997 11:27:41 GMT

Distribution: World

> 
> 1. we are losing ATM cells which might be perfectly alright, because of an
> *ANOMALY* ( Though one of the IMA objectives is that Cells should not be
> sent misordered to the ATM layer). Is it a good thing to do ?
	
In ATM, misordering of cells is not at all allowed, even if it is at the
cost
of *dropping* cells.  Misordering could be detected in AAL5 connections
through
CRC verification, but if the connection type is AAL1, then it is going
to be
problematic.

> 
> 2. Since the link is out of round-robin, effective incoming cell rate
> decreases. To handle this do we decrease the IDCR, or introduce Filler
> cells, on behalf of the link that is down, so that IDCR remains same ?
	
Requirement (R-104) in the latest specs. (af-phy-0086.000) answers this
question.

Hope it helps,
-ramkumar