Cell Relay Archive[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index][Thread Index][Author Index][Subject Index] Re: IMA: Handling anomaly condition
Distribution: World > > 1. we are losing ATM cells which might be perfectly alright, because of an > *ANOMALY* ( Though one of the IMA objectives is that Cells should not be > sent misordered to the ATM layer). Is it a good thing to do ? In ATM, misordering of cells is not at all allowed, even if it is at the cost of *dropping* cells. Misordering could be detected in AAL5 connections through CRC verification, but if the connection type is AAL1, then it is going to be problematic. > > 2. Since the link is out of round-robin, effective incoming cell rate > decreases. To handle this do we decrease the IDCR, or introduce Filler > cells, on behalf of the link that is down, so that IDCR remains same ? Requirement (R-104) in the latest specs. (af-phy-0086.000) answers this question. Hope it helps, -ramkumar |
|