Re: Question on Data-VCC creation...

  • From: Sripriya Raghunathan <sripriyar@yahoo.com>
  • Date: 23 Jul 1998 20:44:28 GMT

Hi Ronald,

If you are doing your signaling in some VPI (say 10) other than the
default VPI 0, then then data VCC should also be created in the same
VPI (10) in which signaling is done. This is called associated
signaling. 

This associated signaling what you have asked, is not allowed in
UNI3.1 and UNI4.0. This is allowed only in PNNI Signaling right now.

If the signaling is done in VPI 0, then data VCC can be created in any
of the other VPIs also. This is called non associated signaling.

Hope this helps,
Regards,
Sripriya Raghunathan