Re: Doubt in draft-ietf-mpls-te-mib-07.txt
-
From: Thomas Nadeau <tnadeau@cisco.com>
-
Date: Mon, 22 Oct 2001 09:30:20 -0400
-
Cc: mpls@UU.NET, mpls-ops@mplsrc.com
-
Resent-Date: Mon, 22 Oct 2001 12:00:54 -0400
-
To: "Ashwin C. Prabhu" <Ashwinp@in.huawei.com>
-
X-Sender: tnadeau@bucket.cisco.com
In draft-ietf-mpls-te-mib-07.txt mplsTunnelTotalUpTime &
mplsTunnelInstanceUpTime are read-create ?
shouldn't this
be read-only ?
Yes. This
is a typo that has been pointed out several times, and will
be corrected in the next revision. Thanks.
--Tom
Ashwin
mplsTunnelTotalUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value represents the aggregate up time for all
instances of this tunnel, if available. If this
value is unavailable, it MUST return a value of 0."
::= { mplsTunnelEntry 32 }
mplsTunnelInstanceUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value identifies the total time that this
tunnel instance's operStatus has been Up(1)."
::= { mplsTunnelEntry 33 }
------------------------------------------------------------------------
Mathematics is the supreme nostalgia of our time.
| |
|