The MPLS-OPS Archive[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index][Thread Index][Author Index][Subject Index] MTU problems in EoMpls domain..
hi all,
I am new to this mailing list. so hi to all.. now
my problems :((
Actually, I am trying to handle the problem of fragmentation in
Ethernet over MPLS network.
This is the existing network
topology...
LAN A -------> MPLS
Domain ----------> LAN B
To implement EoMPLS, I am capturing the packet in
Ingress of the MPLS domain
and trying to send this as a payload over the MPLS
domain.. When I
am doing this the problem is that the frames which
are 1500 bytes (normal
ethernet frames) can not be sent across this MPLS
domain as the payld
of this domain can only be 1496 bytes... (4 bytes
label gets added and leave
the matter when multiple labels are added)..
So, I am stuck as i am not
able to send 1500 bytes frames..
These all things are being carried on test setups.
So, I can not
have the liberty or leisure to use SONET interfaces
as my core n/w
interfaces.. also am not sure what to do in order
to make use of jumbo
ethernet frames... So, the only option left is to
fragment the frames when i
capture the ethernet frames.. but for that i need
ur advice..
I mean is there any standard methodology that says how to handle
fragmentation in ethernet layer cos I will have to anyway go to this
final resort.. or is there any other way arnd. ??
Thanks & Regards
Tarun B _________________________________________________ Tarun Bhalla Wipro Technologies 26 Hosur Main Road, Bommanahalli, Bangalore- 560 068. India Tel +91-80-5732293, Extn 3139 <http://www.wipro.com/>
|
|