Cell Relay Archive

Cell Relay Retreat>List Archive>month:1996-Dec> msg00024



[Date Prev][Date Next][Thread Prev][Thread Next]  
  [Date Index][Thread Index][Author Index][Subject Index]

ATM Simulator(NiST)

  • From: Bernd Reuther <breuther@rhrk.uni-kl.de>
  • Date: Tue, 03 Dec 1996 18:44:24 +0100

-- 
Hi !!

    I am using The NIST ATM Network Simulator(version 2) for simulating
my lab environment .There are some Input information for the ATM switch,
which has to be enetred ,before running the simulator.But there is no
info.in the manual for these factors,I shall be thankful if someone can
help me :

ATM Switch :Input parameters ;
# 1(EFCI), 2(NIST), 3(735R1): 2
        # MACR Additive Increase Rate (Mbits/s): 0.5
        # Target Rate (Mbits/s): 142
        # Explicit Reduction Factor (ERF): 0.9375
        # Measurement Interval in cells (N): 100
        # Congestion Tolerance in cells (tau): 0
        # Initial MACR rate (Mbits/s): 1.492
        # VC Separator: 0.875
        # Average Factor (AV): 0.0625
        # DQT (Cells): 2000
        # Major Reduction Factor (MRF): 0.95
        # Down Pressure Factor (DPF): 0.875
         #Congestion (True/False): 1
         #% cell drop: 0

In the above there is shown some input values given in the sample
configfile of the simulator.

My address :   vyas@rhrl.uni-kl.de
               vyas@mathematik.uni-kl.de