Cell Relay Archive

Cell Relay Retreat>List Archive>month:1997-Dec> msg00149



[Date Prev][Date Next][Thread Prev][Thread Next]  
  [Date Index][Thread Index][Author Index][Subject Index]

RE: Loop Back , data cells.!

  • From: Mike Conner <mconner@sntc.com>
  • Date: 19 Dec 1997 15:28:59 GMT

There should not be any issue in doing this.  In our switch the call
would simply be routed back to the source.  A data connection would be
set up in the switch which simply loops the data back to the sender.
Our host UNIs do not look specifically look for a loopback condition,
except for the one (UNI) which exists within our switch.  They simply
let the network take care of it..

                              
Mike Conner
Senior Design Engineer                                       
Phone: (612) 519-9756
Fax:   (612) 519-9701

SNT (Switched Network Technologies, Inc.) 
3550 Annapolis Lane North                 
Suite 10                                  
Plymouth, MN 55447-5333 
http:\\www.sntc.com  

Editorials or answers to questions are based on technical experience, to
the best of my knowledge, and are not necessarily views or opinions of
SNT, Inc. 



> ----------
> From: 	V B Kumar[SMTP:vbkumar@wipinfo.soft.net]
> Reply To: 	V B Kumar
> Sent: 	Thursday, December 18, 1997 4:37 AM
> To: 	cell relay
> Subject: 	CR: Loop Back , data cells.!
> 
> Halo Everyone ,
>                 In UNI signalling procedure, is it possible to send a
> setup
> message with the destination ( called party ) address identical to 
> that of the source ( calling party ) address ?
> What is the behaviour of the edge switch across the UNI in the
> network, 
> does it loop back the data cells, if setup is successful ? . 
> If it is implementation specific, can anyone give me some example 
> switches and their behaviour ?
> 
> 
> 
> Thanks in advance !
> 
> 
> VBKumar.
> 
> 
> 
> 
>