Hi Totti Murakami,

I would suggest you to use the tunnel reoptimization futures to acheive 
the same.

For acheiving 2nd requirment,  You can use the command "mpls traffic-eng 
reoptimize" on the Cisco 7600 routers to manually switchover the tunnels.

For acheiving 3rd requirment, You can use the tunnel lockdown feature.  
So that it will not fall back to primary path.

" tunnel mpls traffic-eng path-option preference {dynamic | explicit 
name name | identifier id>} {lockdown} "

I hope this helps.

Regards

Balaji,
baalaji@yahoo.com



Totti Murakami wrote:

>Hi All,
>
>I am plannning to deploy rsvp-te based MPLS network with Cisco7600.
>And there are some requirements for the network.
>
>1) Primary path and secondary path for an lsp are configured explicitly.
>2) Primary path is used normally. But when the maintainance is required, the path is manually 
>changed to secondary. Then it must be changed without packet loss.
>3) The path must not be back to primary automatically.
>
>For achieving the above requirements,
>I wonder that I should configure two tunnels for one destination and change administrative-weight of 
>each of them. But if this configuration is used, rsvp-information will not reflect the real 
>bandwidth design compared to when using path-option in the tunnel configuration.
>
>Is there any reasonable way to meet these requirements?
>Would you tell me how it should be configured?
>
>Thanks in advance,
>-Totti Murakami
>
>-------
>The MPLS-OPS Mailing List
>Subscribe/Unsubscribe:  http://www.mplsrc.com/mplsops.shtml
>Archive: http://www.mplsrc.com/mpls-ops_archive.shtml
>
>MPLScon 2005 - May 16-19, NYC, NY
>http://www.mplscon.com/
>
>  
>
********** DISCLAIMER **********
Information contained and transmitted by this E-MAIL is proprietary to 
Sify Limited and is intended for use only by the individual or entity to 
which it is addressed, and may contain information that is privileged, 
confidential or exempt from disclosure under applicable law. If this is a 
forwarded message, the content of this E-MAIL may not have been sent with 
the authority of the Company. If you are not the intended recipient, an 
agent of the intended recipient or a  person responsible for delivering the 
information to the named recipient,  you are notified that any use, 
distribution, transmission, printing, copying or dissemination of this 
information in any way or in any manner is strictly prohibited. If you have 
received this communication in error, please delete this mail & notify us 
immediately at admin@sifycorp.com

-------
The MPLS-OPS Mailing List
Subscribe/Unsubscribe:  http://www.mplsrc.com/mplsops.shtml
Archive: http://www.mplsrc.com/mpls-ops_archive.shtml

MPLScon 2005 - May 16-19, NYC, NY
http://www.mplscon.com/